For laboratory research only. Not for human or veterinary use.

Batch # sr-cu100-260720-002GHK-Cu 100mg

100mg Active

Independent lab report COA-2026-LUYZFM (analyzed 08/11/2026): 99.45% HPLC purity, 105.17 mg net peptide content, identity confirmed, heavy metals not detected, sterility screen no growth, endotoxin 0.089 EU/mL, fentanyl not detected.

Independent lab report

Commissioned by Source Research from an independent lab, separate from the supplier. Values below are copied from the report as printed.

Testing lab
ILS Laboratories
COA #
COA-2026-LUYZFM
Batch #
sr-cu100-260720-002
Analysis date
08/11/2026
Date received
07/22/2026
Labeled content (as submitted)
100mg
Method
Full QC Panel
Appearance
Good
Vials tested
1 of 20
Fentanyl
Not Detected (immunoassay, 50 ng/mL cutoff)
Overall result (as printed)
PASS
Full QC panel
AnalyteSpecificationResultStatus
Peptide Purity (HPLC)>= 95.0%99.45%PASS
Net Peptide ContentReport Only105.17 mgN/A
Identity (HPLC-RTM)GHK-CuConfirmedPASS
Fentanyl ScreenImmunoassay, 50 ng/mL cutoffNot DetectedPASS
Heavy metals (ICP-MS)
TestSpecificationResultStatus
Arsenic (As)NMT 1.5 ppmNot DetectedPASS
Cadmium (Cd)NMT 0.5 ppmNot DetectedPASS
Lead (Pb)NMT 1.0 ppmNot DetectedPASS
Mercury (Hg)NMT 1.5 ppmNot DetectedPASS
Chromium (Cr)NMT 10.0 ppmNot DetectedPASS
Sterility (PCR)
TestSpecificationResultStatus
Sterility (PCR)No GrowthNo GrowthPASS
Endotoxin (USP <85>)
TestSpecificationResultStatus
Endotoxin (USP <85>)Report Result0.089 EU/mLReported

Methods, as stated in the report

  • Identity confirmed by HPLC: chromatographic retention time comparison with a reference standard.
  • Peptide purity determined by RP-HPLC area normalization at 214 nm (target peptide relative to all peptide-related peaks).
  • Elemental impurities analyzed by ICP-MS per USP <233> methodology. Acceptance criteria are internal laboratory quality screening limits for research-use materials.
  • Endotoxin tested per USP <85> kinetic turbidimetric method. Reported as a quantitative value; the report states no universal pass/fail threshold applies to research-use products.

Report links: Verify page · PDF

Supplier COA

The supplier’s own certificate of analysis for this material, issued by the supplier’s laboratory and not commissioned by Source Research. Supplier lot identifiers can differ from Source Research lot numbers, and its test panel differs from the independent lab panel above.

View supplier COA (PDF)

All GHK-Cu 100mg lots · All testing records

For laboratory research use only. Results relate only to the sample tested.